Overcharged batteries behind Dreamliner woes
Experts say Boeing 787 incidents likely caused by overcharged batteries
By Korea HeraldPublished : Jan. 20, 2013 - 20:16
WASHINGTON (AP) ― It’s likely that burning lithium ion batteries on two Boeing 787 Dreamliners were caused by overcharging, aviation safety and battery experts said Friday, pointing to developments in the investigation of the Boeing incidents as well as a battery fire in a business jet more than a year ago.
An investigator in Japan, where a 787 made an emergency landing earlier this week, said the charred insides of the plane’s lithium ion battery show the battery received voltage in excess of its design limits.
The similarity of the burned battery from the All Nippon Airways flight to the burned battery in a Japan Airlines 787 that caught fire Jan. 7 while the jet was parked at Boston’s Logan International Airport suggests a common cause, Japan transport ministry investigator Hideyo Kosugi said.
“If we compare data from the latest case here and that in the U.S., we can pretty much figure out what happened,” Kosugi said.
In the case of the 787 in Boston, the battery in the plane’s auxiliary power unit had recently received a large demand on its power and was in the process of charging when the fire ignited, a source familiar with the investigation of the 787 fire in Boston told the Associated Press. The plane had landed a short time earlier and was empty of passengers, although a cleaning crew was working in the plane.
The source spoke on condition of anonymity because he wasn’t authorized to speak publicly.
The Federal Aviation Administration issued an emergency order Wednesday temporarily grounding the six 787s belonging to United Airlines, the lone U.S. carrier operating Boeing’s newest and most technologically advanced airliner. The Japanese carriers already had grounded their 787s, and airlines and civil aviation authorities in other countries followed suit, shutting down all 50 Dreamliners that Boeing has delivered so far.
Boeing said Friday it will stop delivering new 787s to customers until the electrical system is fixed. However, production is not stopping. The plane is assembled in Everett, Wash., and North Charleston, S.C. The aircraft maker has booked orders for more than 800 of the planes from airlines around the world attracted by its increased fuel efficiency.
A battery fire in a Cessna Citation CJ4, a business jet, prompted the Federal Aviation Administration in October 2011 to issue an emergency order requiring the lithium ion batteries in all 42 of the jets in operation at that time to be replaced with a conventional nickel-cadmium or lead-acid battery. The fire occurred while the plane was hooked up to a ground power station at Cessna’s aircraft completion center in Wichita, Kan. Normally, that would cause an aircraft battery to automatically start charging, experts said.
A letter from Cessna to CJ4 owners after the incident cautioned: “Do not connect a ground power unit to the airplane if you have reason to believe the battery may be in a depleted state ... Do not leave the aircraft unattended with a ground power unit connected.”
The Citation was Cessna’s first business jet with a lithium ion battery as its main battery, and the 787 is the first airliner to make extensive use of lithium ion batteries. But the two are vastly different in size and in other respects, including their electrical systems, making comparisons difficult. Their batteries also came from different makers. The reasons they overcharged are likely to be different, experts said.
However, the three incidents ―the two burned 787 batteries and the Citation fire ― underscore the vulnerability of lithium ion batteries to igniting if they receive too much voltage too fast, experts said. Other types of batteries may overheat in those circumstances, but they are far less susceptible to starting a fire, they said.
An investigator in Japan, where a 787 made an emergency landing earlier this week, said the charred insides of the plane’s lithium ion battery show the battery received voltage in excess of its design limits.
The similarity of the burned battery from the All Nippon Airways flight to the burned battery in a Japan Airlines 787 that caught fire Jan. 7 while the jet was parked at Boston’s Logan International Airport suggests a common cause, Japan transport ministry investigator Hideyo Kosugi said.
“If we compare data from the latest case here and that in the U.S., we can pretty much figure out what happened,” Kosugi said.
In the case of the 787 in Boston, the battery in the plane’s auxiliary power unit had recently received a large demand on its power and was in the process of charging when the fire ignited, a source familiar with the investigation of the 787 fire in Boston told the Associated Press. The plane had landed a short time earlier and was empty of passengers, although a cleaning crew was working in the plane.
The source spoke on condition of anonymity because he wasn’t authorized to speak publicly.
The Federal Aviation Administration issued an emergency order Wednesday temporarily grounding the six 787s belonging to United Airlines, the lone U.S. carrier operating Boeing’s newest and most technologically advanced airliner. The Japanese carriers already had grounded their 787s, and airlines and civil aviation authorities in other countries followed suit, shutting down all 50 Dreamliners that Boeing has delivered so far.
Boeing said Friday it will stop delivering new 787s to customers until the electrical system is fixed. However, production is not stopping. The plane is assembled in Everett, Wash., and North Charleston, S.C. The aircraft maker has booked orders for more than 800 of the planes from airlines around the world attracted by its increased fuel efficiency.
A battery fire in a Cessna Citation CJ4, a business jet, prompted the Federal Aviation Administration in October 2011 to issue an emergency order requiring the lithium ion batteries in all 42 of the jets in operation at that time to be replaced with a conventional nickel-cadmium or lead-acid battery. The fire occurred while the plane was hooked up to a ground power station at Cessna’s aircraft completion center in Wichita, Kan. Normally, that would cause an aircraft battery to automatically start charging, experts said.
A letter from Cessna to CJ4 owners after the incident cautioned: “Do not connect a ground power unit to the airplane if you have reason to believe the battery may be in a depleted state ... Do not leave the aircraft unattended with a ground power unit connected.”
The Citation was Cessna’s first business jet with a lithium ion battery as its main battery, and the 787 is the first airliner to make extensive use of lithium ion batteries. But the two are vastly different in size and in other respects, including their electrical systems, making comparisons difficult. Their batteries also came from different makers. The reasons they overcharged are likely to be different, experts said.
However, the three incidents ―the two burned 787 batteries and the Citation fire ― underscore the vulnerability of lithium ion batteries to igniting if they receive too much voltage too fast, experts said. Other types of batteries may overheat in those circumstances, but they are far less susceptible to starting a fire, they said.
-